Two dimensional flow analysis of fluid-structure interaction around a tube row and tube arrays in cross-flow

  • 1. Mitsubishi Heavy Industries, Ltd., Takasago R and D Center, Takasago, Hyogo (Japan)
  • 2. Kansai Electric Power Co., Inc., Osaka (Japan)

Description

This paper examines the adequacy of this analytical method by simulating flow induced vibration of tube array, which infinitely continues in the direction at right angles to the flow and is elastically supported, using the moving grid method. The results obtained are compared with existing experimental results. Furthermore, this paper also clarifies various characteristics of flow induced vibration phenomena through this analytical results. (J.P.N.)

Part of:
ICONE-3: Proceedings of the 3rd JSME/ASME joint international conference on nuclear engineering. Volume 1

Additional details

Publishing Information

Imprint Title
ICONE-3: Proceedings of the 3rd JSME/ASME joint international conference on nuclear engineering. Volume 1
Imprint Pagination
701 p.
Journal Page Range
p. 603-608

Conference

Title
3. JSME/ASME joint international conference on nuclear engineering
Acronym
ICONE-3
Dates
23-27 Apr 1995
Place
Kyoto (Japan)

Optional Information

Notes
15 refs., 14 figs., 3 tabs.