Published June 1983 | Version v1
Report Open

Measurement of damping time and frequency of coherent synchrotron oscillation in PF storage ring

Description

The damping time and the frequency of the coherent synchrotron oscillation in the PF storage ring were studied. A weak beam phase oscillation was induced by feeding an external perturbation to an acceleration phase control circuit, and the beam oscillation was measured with a signal from a beam position monitor. Observed damping was much stronger than that of the calculated value using the Robinson damping mechanism. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

16046097.pdf

Files (179.5 kB)

Name Size Download all
md5:6427760b630354b25c869329c582157e
179.5 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
12 p.
Report number