Published June 1982 | Version v1
Report Open

Fault tree analysis on BWR core spray system

  • 1. Japan Atomic Energy Research Inst., Tokai, Ibaraki. Tokai Research Establishment

Description

Fault Trees which describe the failure modes for the Core Spray System function in the Browns Ferry Nuclear Plant (BWR 1065MWe) were developed qualitatively and quantitatively. The unavailability for the Core Spray System was estimated to be 1.2 x 10-3/demand. It was found that the miscalibration of four reactor pressure sensors or the failure to open of the two inboard valves (FCV 75-25 and 75-53) could reduce system reliability significantly. It was recommended that the pressure sensors would be calibrated independently. The introduction of the redundant inboard valves could improve the system reliability. Thus this analysis method was verified useful for system analysis. The detailed test and maintenance manual and the informations on the control logic circuits of each active component are necessary for further analysis. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

14771899.pdf

Files (3.5 MB)

Name Size Download all
md5:bbbc605223375ff46dd400faafcec2f3
3.5 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
112 p.
Report number
JAERI-M--82-060