Mechanical system for magnetic field measurement through central axis and inside magnetic channels for VEC K-500 cyclotron

  • 1. Variable Energy Cyclotron Centre, Kolkata (India)

Description

An accurate measurement of magnetic field inside the superconducting cyclotron is required to properly inject, accelerate and extract the beam from cyclotron. A magnetic field measuring device has been fabricated to measure the magnetic field inside the superconducting cyclotron. Two other mechanical systems are being, fabricated to measure the magnetic field along the beam injection and extraction path. This paper presents all mechanical features of the driving mechanisms. (author)

Part of:
DAE-BRNS Indian particle accelerator conference-2005

Additional details

Publishing Information

Publisher
Variable Energy Cyclotron Centre
Imprint Place
Kolkata (India)
Imprint Title
DAE-BRNS Indian particle accelerator conference-2005
Imprint Pagination
628 p.
Journal Page Range
p. 517-518

Conference

Title
DAE-BRNS Indian particle accelerator conference
Acronym
InPAC-2005
Dates
1-5 Mar 2005
Place
Kolkata (India)

INIS

Country of Publication
India
Country of Input or Organization
India
INIS RN
37006653
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAM DYNAMICS; BEAM EXTRACTION; BEAM INJECTION; FABRICATION; MAGNETIC FIELDS; MEASURING INSTRUMENTS; SUPERCONDUCTING CYCLOTRONS
Descriptors DEC
ACCELERATORS; CYCLIC ACCELERATORS; CYCLOTRONS; DYNAMICS; MECHANICS

Optional Information

Notes
2 refs., 3 figs.