Published March 2005
| Version v1
Book
Mechanical system for magnetic field measurement through central axis and inside magnetic channels for VEC K-500 cyclotron
Creators
- 1. Variable Energy Cyclotron Centre, Kolkata (India)
Description
An accurate measurement of magnetic field inside the superconducting cyclotron is required to properly inject, accelerate and extract the beam from cyclotron. A magnetic field measuring device has been fabricated to measure the magnetic field inside the superconducting cyclotron. Two other mechanical systems are being, fabricated to measure the magnetic field along the beam injection and extraction path. This paper presents all mechanical features of the driving mechanisms. (author)
Additional details
Publishing Information
- Publisher
- Variable Energy Cyclotron Centre
- Imprint Place
- Kolkata (India)
- Imprint Title
- DAE-BRNS Indian particle accelerator conference-2005
- Imprint Pagination
- 628 p.
- Journal Page Range
- p. 517-518
Conference
- Title
- DAE-BRNS Indian particle accelerator conference
- Acronym
- InPAC-2005
- Dates
- 1-5 Mar 2005
- Place
- Kolkata (India)
INIS
- Country of Publication
- India
- Country of Input or Organization
- India
- INIS RN
- 37006653
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BEAM DYNAMICS; BEAM EXTRACTION; BEAM INJECTION; FABRICATION; MAGNETIC FIELDS; MEASURING INSTRUMENTS; SUPERCONDUCTING CYCLOTRONS
- Descriptors DEC
- ACCELERATORS; CYCLIC ACCELERATORS; CYCLOTRONS; DYNAMICS; MECHANICS
Optional Information
- Notes
- 2 refs., 3 figs.