The influence of construction measurement and structure storey on seismic performance of masonry structure

  • 1. Institute of Engineering Mechanics, China Earthquake Administration, Harbin 150080 (China)

Description

The damage of masonry structures in earthquakes is generally more severe than other structures. Through the analysis of two typical earthquake damage buildings in the Wenchuan earthquake in Xuankou middle school, we found that the number of storeys and the construction measures had great influence on the seismic performance of masonry structures. This paper takes a teachers' dormitory in Xuankou middle school as an example, selected the structure arrangement and storey number as two independent variables to design working conditions. Finally we researched on the seismic performance difference of masonry structure under two variables by finite element analysis method. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1755-1315/81/1/012135

Additional details

Publishing Information

Journal Title
IOP Conference Series: Earth and Environmental Science (Online)
Journal Volume
81
Journal Issue
1
Journal Page Range
[6 p.]
ISSN
1755-1315

Conference

Title
2. International Conference on Materials Science, Energy Technology and Environmental Engineering
Acronym
MSETEE 2017
Dates
28-30 Apr 2017
Place
Zhuhai (China)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
52097155
Subject category
S58: GEOSCIENCES;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CONSTRUCTION; DAMAGE; EARTHQUAKES; EDUCATIONAL FACILITIES; FINITE ELEMENT METHOD; PERFORMANCE; RESIDENTIAL BUILDINGS; WORKING CONDITIONS
Descriptors DEC