Published October 2008 | Version v1
Journal article

Beam parameter determination using beamstrahlung photons and incoherent pairs

  • 1. Linear Collider Group, DESY, Platanenallee 6, 15738 Zeuthen (Germany)
  • 2. Dzhelepov Laboratory of Nuclear Problems, Joint Institute of Nuclear Research, Joliot-Curie 6, 141980 Dubna, Moscow region (Russian Federation)

Description

The beam calorimeter BeamCal and the photon calorimeter GamCal of the ILC detectors will be used to obtain a set of parameters describing the beam properties at the interaction point. The real-time determination of the parameters is a challenge, but is mandatory to achieve the best possible luminosity for the ILC. We report on our studies about the possibilities to reduce the number of readout channels of BeamCal without significant loss of precision in the beam parameter determination. In addition, the benefit of measuring the beamstrahlung photons energy using GamCal is evaluated. Finally we report on the achievable precision of and the observed correlations between the beam parameters reconstructed in the multi-parameter regime. We also comment on possible solutions how to deal with these correlations.

Availability note (English)

Available from http://dx.doi.org/10.1088/1748-0221/3/10/P10004

Additional details

Publishing Information

Journal Title
Journal of Instrumentation
Journal Volume
3
Journal Issue
10
Journal Page Range
p. P10004
ISSN
1748-0221

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
41013913
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
ACCURACY; BEAMS; CALORIMETERS; CORRELATIONS; LUMINOSITY; PHOTONS; READOUT SYSTEMS; SHOWER COUNTERS
Descriptors DEC
BOSONS; ELEMENTARY PARTICLES; MASSLESS PARTICLES; MEASURING INSTRUMENTS; OPTICAL PROPERTIES; PHYSICAL PROPERTIES; RADIATION DETECTORS