Published March 2006 | Version v1
Journal article

Evaluation of fuel temperature on high temperature test operation at high temperature gas-cooled reactor 'HTTR'

  • 1. Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan)
  • 2. Fuji Electric Systems Co., Ltd., Kawasaki, Kanagawa (JP)

Description

High Temperature Engineering Test Reactor (HTTR) of high temperature gas-cooled reactor at Japan Atomic Energy Agency (JAEA) achieved the reactor outlet coolant temperature of 950degC for the first time in the world at Apr. 19, 2004. To ensure the thermal integrity of fuel in high temperature test operation, it is necessary that fuel temperature is designed appropriately by fuel temperature designing method, and that estimated maximum fuel temperature is lower than the thermal limit temperature. In this report, by constructing newly a realistic core-shape representing model, the current fuel temperature estimation model is improved. Moreover fuel temperature in high-temperature test operation is estimated with the newly-constructed model, and it is confirmed that estimated maximum fuel temperature in high temperature test operation is lower than the thermal limit temperature. (author)

Additional details

Publishing Information

Journal Title
Nippon Genshiryoku Gakkai Wabun Ronbunshi
Journal Volume
5
Journal Issue
1
Journal Page Range
p. 57-67
ISSN
1347-2879

Optional Information

Notes
13 refs., 15 figs., 4 tabs.