Implementation of a parallel-beam optical-CT apparatus for three-dimensional radiation dosimetry using a high-resolution CCD camera
- 1. Department of Computer Science and Information Engineering, Minghsin University of Science and Technology, Taiwan, ROC (China)
- 2. Department of Management Information Systems, Central Taiwan University of Science and Technology, Taichung, Taiwan, ROC (China)
- 3. Graduate Institute of Computer and Communication Engineering, National Taipei University of Technology, Taiwan, ROC (China)
- 4. Institute of Biomedical Engineering and Materials Science, Central Taiwan University of Science and Technology, Taichung, Taiwan, ROC (China)
Description
In this study, a charge-coupled device (CCD) camera with 2-megapixel (1920×1080-pixel) and 12-bit resolution was developed for optical computed tomography(optical CT). The signal-to-noise ratio (SNR) of our system was 30.12 dB, better than that of commercially available CCD cameras (25.31 dB). The 50% modulation transfer function (MTF50) of our 1920×1080-pixel camera gave a line width per picture height (LW/PH) of 745, which is 73% of the diffraction-limited resolution. Compared with a commercially available 1-megapixel CCD camera (1296×966-pixel) with a LW/PH=358 and 46.6% of the diffraction-limited resolution, our camera system provided higher spatial resolution and better image quality. The NIPAM gel dosimeter was used to evaluate the optical CT with a 2-megapixel CCD. A clinical five-field irradiation treatment plan was generated using the Eclipse planning system (Varian Corp., Palo Alto, CA, USA). The gel phantom was irradiated using a 6-MV Varian Clinac IX linear accelerator (Varian). The measured NIPAM gel dose distributions and the calculated dose distributions, generated by the treatment planning software (TPS), were compared using the 3% dose-difference and 3 mm distance-to-agreement criteria. The gamma pass rate was as high as 98.2% when 2-megapixel CCD camera was used in optical CT. However, the gamma pass rate was only 96.0% when a commercially available 1-megapixel CCD camera was used. - Highlights: • An optical CT system with a 2-megapixel CCD showed high uniformity of reconstructed images of the gel phantom. • The gamma pass rate was as high as 98.2% with the 3% dose difference and 3 mm dose to agreement criteria. • Our CCD with 12-bit information could guarantee better SNR performance, of 30.12 dB. • Our 2-megapixel CCD camera gave a LW/PH of 745, 73% of the diffraction-limited resolution
Availability note (English)
Available from http://dx.doi.org/10.1016/j.nima.2015.01.050Additional details
Identifiers
- DOI
- 10.1016/j.nima.2015.01.050;
- PII
- S0168-9002(15)00081-9;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 784
- Journal Page Range
- p. 590-596
- ISSN
- 0168-9002
- CODEN
- NIMAER
Conference
- Title
- 15. symposium on radiation measurements and applications
- Acronym
- SORMA XV
- Dates
- 9-12 Jun 2014
- Place
- Ann Arbor, MI (United States)
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47027550
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CHARGE-COUPLED DEVICES; COMPUTER CODES; COMPUTERIZED TOMOGRAPHY; DOSEMETERS; DOSIMETRY; IRRADIATION; LINE WIDTHS; LINEAR ACCELERATORS; PHANTOMS; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; SPATIAL RESOLUTION
- Descriptors DEC
- ACCELERATORS; DIAGNOSTIC TECHNIQUES; DOSES; MEASURING INSTRUMENTS; MOCKUP; RESOLUTION; SEMICONDUCTOR DEVICES; STRUCTURAL MODELS; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2015 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.