Methods to verify absorbed dose of irradiated containers and evaluation of dosimeters
- 1. Institute for Application of Atomic Energy, Chinese Academy of Agricultural Sciences, Beijing (China)
Description
The research on dose distribution in irradiated food containers and evaluation of several methods to verify absorbed dose were carried out. The minimum absorbed dose of treated five orange containers was in the top of the highest or in the bottom of lowest container. Dmax/Dmin in this study was 1.45 irradiated in a commercial 60Co facility. The density of orange containers was about 0.391g/cm3. The evaluation of dosimeters showed that the PMMA-YL and clear PMMA dosimeters have linear relationship with dose response, and the word NOT in STERIN-125 and STERIN-300 indicators were covered completely at the dosage of 125 and 300 Gy respectively. (author)
Files
32017960.pdf
Files
(149.8 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:9aab0e76a68ac90f8b0a4cded5589363
|
149.8 kB | Preview Download |
Additional details
Publishing Information
- Imprint Title
- Standardized methods to verify absorbed dose in irradiated food for insect control. Proceedings of a final research co-ordination meeting
- Imprint Pagination
- 129 p.
- Journal Page Range
- p. 91-96
- ISSN
- 1011-4289
- Report number
- IAEA-TECDOC--1201
Conference
- Title
- Final research co-ordination meeting on standardized methods to verify absorbed dose in irradiated food for insect control
- Dates
- 30 Mar - 3 Apr 1998
- Place
- Cascais (Portugal)
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 32017960
- Subject category
- S60: APPLIED LIFE SCIENCES; S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CHEMICAL DOSEMETERS; FOOD PROCESSING; FRUITS; GAMMA DETECTION; PMMA; RADIATION DETECTION; RADIATION DOSES; RADIODISINFESTATION; STANDARDIZATION; TRADE
- Descriptors DEC
- DETECTION; DISINFESTATION; DOSEMETERS; DOSES; ESTERS; FOOD; IRRADIATION; MEASURING INSTRUMENTS; ORGANIC COMPOUNDS; ORGANIC POLYMERS; POLYACRYLATES; POLYMERS; POLYVINYLS; PROCESSING; RADIATION DETECTION
Optional Information
- Contract/Grant/Project number
- Contract 7980
- Notes
- 6 refs, 4 figs, 3 tabs