Published November 7, 2009 | Version v1
Journal article

Theoretical analysis of full-ring multi-pinhole brain SPECT

  • 1. Image Sciences Institute, University Medical Center Utrecht, STR 5.203, Universiteitsweg 100, 3584 CG Utrecht (Netherlands)

Description

Presently used clinical brain SPECT suffers from limited spatio-temporal resolution. Here we investigate the feasibility of high-resolution and high-sensitivity full-ring multi-pinhole brain SPECT (MP-SPECT). Using an analytical model we optimized pinhole-detector geometries of MP-SPECT for different detector intrinsic resolutions Ri. System resolution and sensitivity of optimized MP-SPECT were compared to conventional clinical SPECT. The comparison of the system resolution of different systems was done at matched sensitivity, which was achieved by tuning pinhole diameters. Similarly, sensitivities were compared at matched system resolution. For MP-SPECT that uses detectors with intrinsic resolutions of 4 mm > Ri ≥ 0.5 mm a sensitivity can be achieved that is 6.0 times higher than the sensitivity of conventional dual-head SPECT systems with parallel-hole collimators (DualPar), while system resolution can be improved by a factor of 2.4. To achieve these improvements a large detector-to-collimator distance is needed. In contrast, for detectors with intrinsic resolutions <0.2 mm, it is beneficial to place the detectors close to the pinholes, resulting in a high number of de-magnified projections. For a detector intrinsic resolution of 0.05 mm, a 14.5-fold improvement in sensitivity and a 3.8-fold improvement in system resolution compared to DualPar is predicted. Furthermore, we found that for optimized MP-SPECT the sensitivity scales proportionally to system resolution squared, with the proportionality constant depending on Ri. From our sensitivity-system resolution trade-off equations we deduced that MP-SPECT with an ideal detector (Ri → 0) can have a system resolution that is 2.0 times better than optimized MP-SPECT with a conventional detector (Ri ≅ 3 mm). The high performance of optimized MP-SPECT may open up completely new molecular imaging applications.

Availability note (English)

Available from http://dx.doi.org/10.1088/0031-9155/54/21/010

Additional details

Identifiers

DOI
10.1088/0031-9155/54/21/010;
PII
S0031-9155(09)20670-1;

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
54
Journal Issue
21
Journal Page Range
p. 6593-6610
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
41062375
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BRAIN; OPTIMIZATION; RESOLUTION; SENSITIVITY; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY
Descriptors DEC
BODY; CENTRAL NERVOUS SYSTEM; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; NERVOUS SYSTEM; ORGANS; TOMOGRAPHY