Published January 1, 1990
| Version v1
Journal article
Scintillating fiber ribbon-tungsten calorimeter
Creators
- 1. Fermi National Accelerator Lab., Batavia, IL (USA)
- 2. Illinois Univ., Urbana (USA)
Description
We describe an ultra-high density scintillating fiber and tungsten calorimeter used as an active beam-dump for electrons. Data showing the calorimeter response to electrons with momenta between 50 and 350 GeV/c are presented. (orig.)
Additional details
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research, Section A
- Journal Volume
- 286
- Journal Issue
- 1/2
- Series
- Nucl. Instrum. Methods Phys. Res., Sect. A.
- Journal Page Range
- 69-72
- ISSN
- 0168-9002
- CODEN
- NIMAE
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 21036981
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ATTENUATION; BEAM DUMPS; CALORIMETERS; CASCADE SHOWERS; DOPED MATERIALS; ELECTRON DETECTION; FIBER OPTICS; GEV RANGE 10-100; GEV RANGE 100-1000; PHOSPHORUS; PLASTIC SCINTILLATION DETECTOR; POLYSTYRENE; RELATIVISTIC RANGE; RESPONSE FUNCTIONS; SHOWER COUNTERS; TUNGSTEN
- Descriptors DEC
- CHARGED PARTICLE DETECTION; DETECTION; ELEMENTS; ENERGY RANGE; FUNCTIONS; GEV RANGE; MATERIALS; MEASURING INSTRUMENTS; METALS; NONMETALS; OPTICS; ORGANIC COMPOUNDS; ORGANIC POLYMERS; POLYMERS; POLYOLEFINS; POLYVINYLS; RADIATION DETECTION; RADIATION DETECTORS; SCINTILLATION COUNTERS; SHOWERS; SOLID SCINTILLATION DETECTORS; TRANSITION ELEMENTS