Published November 1979 | Version v1
Report Open

Shielding and maintainability in an experimental tokamak

  • 1. Argonne National Lab., IL

Description

This paper presents the results of an attempt to develop an understanding of the various factors involved. This work was performed as a part of the task assigned to one of the expert groups on the International Tokamak Reactor (INTOR). The shielding penalties for requiring personnel access are quantified. This is followed by a quantitative estimate of the benefits associated with personnel access. The penalties to the benefits and conclusions and recommendations on resolving the issue are discussed

Files

11539351.pdf

Files (261.9 kB)

Name Size Download all
md5:f00a6e0f30eeb22c165031f18dcdcc24
261.9 kB Preview Download

Additional details

Publishing Information

Imprint Title
Recent contributions to fusion reactor design and technology development
Journal Page Range
p. 54-59.
Report number
ANL/FPP/TM--127

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
11539351
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Descriptors DEI
MAINTENANCE; PERSONNEL; REMOTE HANDLING; SAFETY; SHIELDING; THERMONUCLEAR REACTORS