Antiproton Accumulator in the Main Injector era (2)
Description
By adding a single quadrupole per sextant in the Antiproton Accumulator it is possible to obtain a lattice well suited for higher bandwidth stochastic cooling systems such as those anticipated for the Main Injector era. The lattice proposed here has excellent properties concerning both the lattice functions and the stochastic cooling parameters
Availability note (English)
MF available from INIS under the Report Number; OSTI as DE93008366; NTIS; INIS; US Govt. Printing Office Dep.
Files
Additional details
Publishing Information
- Imprint Pagination
- 11 p.
- Report number
- FNAL-TM--1812
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 24047575
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- ANTIPROTON BEAMS; BEAM INJECTION; BUILDUP; QUADRUPOLES; STOCHASTIC COOLING; TUNING
- Descriptors DEC
- ANTINUCLEON BEAMS; ANTIPARTICLE BEAMS; BEAM COOLING; BEAMS; MULTIPOLES