Seismic fragility capacity of equipment
Creators
- 1. Japan Nuclear Energy Safety Organization, Safety Standard Division, Tokyo (Japan)
Description
Seismic probabilistic safety assessment (PSA) is an available method to evaluate residual risks of nuclear plants that are designed on definitive seismic conditions. From our preliminary seismic PSA analysis, horizontal shaft pumps are important components that have significant influences on the core damage frequency (CDF). An actual horizontal shaft pump and some kinds of elements were tested to evaluate realistic fragility capacities. Our test results showed that the realistic fragility capacity of horizontal shaft pump would be at least four times as high as a current value, 1.6 x 9.8 m/s2, used for our seismic PSA. We are going to incorporate the fragility capacity data that were obtained from those tests into our seismic PSA analysis, and we expect that the reliability of seismic PSA should increase. (author)
Additional details
Publishing Information
- Journal Title
- Nippon Genshiryoku Gakkai Wabun Ronbunshi
- Journal Volume
- 5
- Journal Issue
- 3
- Journal Page Range
- p. 200-208
- ISSN
- 1347-2879
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 38007381
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- BALL BEARINGS; DYNAMIC LOADS; MECHANICAL SHAFTS; MECHANICAL VIBRATIONS; NUCLEAR POWER PLANTS; PROBABILISTIC ESTIMATION; PUMPS; REACTOR CORE DISRUPTION; SAFETY ANALYSIS; SEISMIC EFFECTS
- Descriptors DEC
- ACCIDENTS; BEARINGS; CALCULATION METHODS; EQUIPMENT; MACHINE PARTS; NUCLEAR FACILITIES; POWER PLANTS; REACTOR ACCIDENTS; THERMAL POWER PLANTS
Optional Information
- Notes
- 10 refs., 18 figs., 5 tabs.