Diagnostic Accuracy of Sonomammography in Diagnosis of BIRADS 4 Suspicious Breast Lesions Keeping Histopathology as Gold Standard
Creators
- 1. Kishwar Fazal Teaching Hospital, Lahore (Pakistan). Dept. of Radiology
- 2. M. Islam Medical and Dental College, Gujranwala (Pakistan)
Description
Objective: To assess the diagnostic accuracy of sonomammography in diagnosis of BIRADS ≥4 suspicious breast lesions taking histopathology as gold standard. Design of the Study: It was a descriptive cross-sectional study. Study Settings: This study was carried out at Department Of Diagnostic Radiology And Diagnostic Imaging Combined Military Hospital, Lahore from January 2017 to June 2017. Material and Methods: A total of 190 patients of age 30-70 years, presenting with palpable breast lesions with BIRAD ≥4 undergoing biopsy under local anesthesia were included. Patients with already diagnosed with breast cancer and recurrent breast lesion were excluded. Then all patients were undergone USG by using a high resolution unit (PLM703AT) with a linear array probe centered at 7, 5 MHz, along with mammography using mamomet 3000 NOVA SIEMENS, General Electric Medical Systems, Milwaukee. Patients were labeled as positive or negative. Sonomammography findings were correlated with histopathological findings. Results of the Study: In 117 sonomammography positive patients, 107 (True Positive) had malignant breast lesions and 08 (False Positive) had benign on histopathology findings. Among, 75 sonomammography negative patients, 06 (False Negative) had malignant breast lesions on histopathology whereas 69 (True Negative) had benign lesions on histopathology. Overall sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of sonomammography in diagnosis of BIRADS ≥4 suspicious breast lesions taking histopathology as gold standard was 94.69%, 89.61%, 93.04%, 92.0% and 92.63% respectively. Conclusion: This study concluded that diagnostic accuracy of sonomammography in diagnosis of BIRADS ≥4 suspicious breast lesions is quite high. (author)
Additional details
Publishing Information
- Journal Title
- Pakistan Journal of Medical and Health Sciences
- Journal Volume
- 15
- Journal Issue
- 10
- Journal Page Range
- p. 2772-2775
- ISSN
- 1996-7195
INIS
- Country of Publication
- Pakistan
- Country of Input or Organization
- Pakistan
- INIS RN
- 52119100
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; ANESTHESIA; BIOPSY; CORRELATIONS; HISTOLOGY; MAMMARY GLANDS; NEOPLASMS; PATHOLOGICAL CHANGES; SPECIFICITY; ULTRASONOGRAPHY
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DISEASES; GLANDS; ORGANS