Published June 2020 | Version v1
Journal article

High-resolution compressed-sensing time-of-flight MRA in a case of acute ICA/MCA dissection

  • 1. Department of Radiology and Nuclear Medicine, University Hospital Basel (Switzerland)
  • 2. Department of Neuroradiology, University Medical Center Freiburg (Germany)
  • 3. Department of Neurology, University Hospital Basel (Switzerland)
  • 4. Department of Neuroradiology, University Hospital Zurich (Switzerland)

Description

Acute, isolated intracranial dissection (ICD) represents a rare and challenging cause of acute stroke. DSA is considered to be the gold standard imaging modality in patients with ICD. The role of novel, high-resolution (HR) compressed-sensing (CS) time-of-flight (TOF) MRA techniques in ICDs is unclear. A 22-year-old male patient with an isolated right ICA/MCA intracranial dissection underwent "conventional" 3-T TOF MRA, HR CS TOF MRA and also DSA including digital rotational angiography. Unlike the "conventional" TOF MRA, HR CS TOF MRA provided comparable image quality to rotational angiography and a dissection membrane was clearly visible in both techniques. In this single case study, we demonstrated the feasibility of a novel HR CS TOF in a case of an acute isolated intracranial ICA/MCA dissection, which needs to be validated in a larger case series.

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00234-020-02395-y

Additional details

Identifiers

Publishing Information

Journal Title
Neuroradiology
Journal Volume
62
Journal Issue
6
Journal Page Range
p. 753-756
ISSN
0028-3940
CODEN
NRDYAB