Published October 2014 | Version v1
Journal article

Passive neutron area monitor with pairs of TLDs as neutron detector

  • 1. Unidad Académica de Estudios Nucleares de la Universidad Autónoma de Zacatecas, C. Ciprés 10, Fracc, La Peñuela, 98068 Zacatecas, Zac. (Mexico)
  • 2. Departamento de Ingeniería Nuclear de la Universidad Politecnica de Madrid, C. Jose Gutierrez Abascal 2, Madrid E-28006 (Spain)

Description

A passive neutron area monitor has been designed using Monte Carlo methods; the monitor is a polyethylene cylinder with pairs of thermoluminescent dosimeters (TLD600 and TLD700) as thermal neutron detector. The monitor was calibrated with a bare and a thermalzed 241AmBe neutron sources and its performance was evaluated measuring the ambient dose equivalent due to photoneutrons produced by a 15 MV linear accelerator for radiotherapy and the neutrons in the output of a TRIGA Mark III radial beam port. - Highlights: • A passive neutron area monitor was built and evaluated. • The monitor uses pairs of TLD 600 and TLD700. • It was evaluated in the beam port of a TRIGA Mark III reactor. • The performance was also evaluated in a 15 MV LINAC

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radmeas.2014.08.006

Additional details

Identifiers

DOI
10.1016/j.radmeas.2014.08.006;
PII
S1350-4487(14)00240-6;

Publishing Information

Journal Title
Radiation Measurements
Journal Volume
68
Journal Page Range
p. 30-34
ISSN
1350-4487
CODEN
RMEAEP

Optional Information

Copyright
Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.