Published 1980 | Version v1
Report Open

Development of nondestructive test

Description

Defect sizing experiment was carried out by using the satellite pulse technique with ultrasonic method. The mode-changed pulses which come from both ends of the artificial flaws in the fabricated sample have been measured on the screen of cathod ray tube with both video mode and radio-frequency mode. The measured values of the flows deviate from the real values less than 10%. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

12596376.pdf

Files (5.8 MB)

Name Size Download all
md5:025320b30985f20793912c5d42625f58
5.8 MB Preview Download

Additional details

Additional titles

Subtitle (English)
Utrasonic test, radiographic test

Publishing Information

Imprint Pagination
p. 8-32.
Report number
KAERI--409/RR-142/80

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
12596376
Subject category
S42: ENGINEERING;
Descriptors DEI
CATHODE RAY TUBES; DEFECTS; PULSE TECHNIQUES; ULTRASONIC TESTING
Descriptors DEC
ACOUSTIC TESTING; ELECTRON TUBES; MATERIALS TESTING; NONDESTRUCTIVE TESTING; TESTING