Published March 1998 | Version v1
Journal article

Intercomparison study of the neutron personnel dosemeters

  • 1. Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

Description

Domestic intercomparison study of the neutron personnel dosemeters was performed for the first time in Korea. Thirteen types of neutron dosemeters from twelve institutions took part in this intercomparison study and the D2O moderated Cf-252 source of KAERI was used for irradiation. Eight of the fifteen dosemeters submitted by each participant were divided into two groups and each group was irradiated with different doses of the simulated mixed fields of neutron and gamma. The participants assessed their dosemeter reading in terms of the personal dose equivalent, Hp(10), for both neutron and gamma dose. The ratio of the reported dose equivalent to the delivered dose equivalent for comparison between participants ranged from 0.55 to 1.334 for neutron, from 0.54 to 1.32 for gamma and from 0.75 to 1.20 for total dose. This intercomparison results show that all dosemeter processors, especially for neutron category, are able to pass the personnel dosemeter performance test which shall be enforced according to the ordinance of the MOST, No.96-6

Additional details

Publishing Information

Journal Title
Journal of the Korean Association for Radiation Protection
Journal Volume
23
Journal Issue
1
Series
11 refs, 2 figs, 5 tabs
Journal Page Range
p. 49-57
ISSN
0253-4231