Thermoluminescence dosemeters are widely used in individual and environmental monitoring. The aim of this work was to compare the thermal stability of dosemeters of the Ext-Rad and whole-body card types with LiF:Mg,Ti and LiF:Mg,Cu,P detectors stored at different temperatures and periods. The dosemeters were stored at 0 deg. C, room temperature and 40 deg. C for periods that lasted 8, 30, 45, 90 and 120 d. In general, TLD-100H detectors present higher TL signal stability than TLD-100 detectors. The intensity of the signal remained constant for both materials for storage periods at 0 deg. C. At RT the same results was observed for TLD-100H. For TLD-100 detectors, a maximum variation of 22 % was registered for the longest period. At 40 deg. C the TL signal decreased with storage time for both detectors. The TL signal of TLD-100H detectors presented maximum variations of 12 % whereas for TLD-100 detectors, larger variations of 25 % were observed. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/ncv445Additional details
Identifiers
- DOI
- 10.1093/rpd/ncv445;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 170
- Journal Issue
- 1-4
- Journal Page Range
- p. 177-180
- ISSN
- 0144-8420
Conference
- Title
- 5. International Conference on Individual Monitoring of Ionising Radiation
- Acronym
- IM2015
- Dates
- 20-24 Apr 2015
- Place
- Bruges (Belgium)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 47099518
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COMPARATIVE EVALUATIONS; LITHIUM FLUORIDES; MONITORING; RADIATION DOSE UNITS; STABILITY; TEMPERATURE RANGE 0273-0400 K; THERMOLUMINESCENT DOSEMETERS; VARIATIONS; WHOLE-BODY COUNTING
- Descriptors DEC
- ALKALI METAL COMPOUNDS; COUNTING TECHNIQUES; DOSEMETERS; EVALUATION; FLUORIDES; FLUORINE COMPOUNDS; HALIDES; HALOGEN COMPOUNDS; LITHIUM COMPOUNDS; LITHIUM HALIDES; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; TEMPERATURE RANGE; UNITS
Optional Information
- Notes
- 11 refs.