An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate
Creators
- 1. Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)
- 2. Graduate School of Human Sciences, Tokyo Metropolitan University, 7-2-10 Higashi-oku, Arakawa-ku, Tokyo 116-8551 (Japan)
- 3. Atomic Energy Research Institute, Kinki University, 3-4-1 Kowakae, Higashiosaka-shi, Osaka 577-8502 (Japan)
- 4. National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-shi, Chiba 263-8555 (Japan)
- 5. Department of Radiology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)
- 6. Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)
Description
In our previous paper, the self-activation of an NaI scintillator had been successfully utilized for detecting photo-neutrons around a high-energy X-ray radiotherapy machine; individual optical pulses from the self-activated scintillator are read-out by photo sensors such as a photomultiplier tube (PMT). In the present work, preliminary observations have been performed in order to apply a direct CCD read-out technique to the self-activation method with a CsI scintillator plate using a Pu-Be source and a 10-MV linac. In conclusion, it has been revealed that the CCD read-out technique is applicable to neutron measurement around a high-energy X-ray radiotherapy machine with the self-activation of a CsI plate. Such application may provide a possibility of novel method for simple neutron dose-distribution measurement. - Highlights: • Preliminary observations have been performed by a CCD for the CsI self-activation method. • It has been revealed that the CCD read-out technique is applicable to neutron measurement. • Such application may provide a novel method for simple neutron distribution measurement.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.nima.2016.06.078Additional details
Identifiers
- DOI
- 10.1016/j.nima.2016.06.078;
- PII
- S0168-9002(16)30642-8;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 832
- Journal Page Range
- p. 21-23
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 48009229
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- CHARGE-COUPLED DEVICES; LINEAR ACCELERATORS; NAI DETECTORS; PHOTOMULTIPLIERS; PHOTONEUTRONS; PULSES; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; RADIOTHERAPY; READOUT SYSTEMS; SENSORS; X RADIATION
- Descriptors DEC
- ACCELERATORS; BARYONS; DOSES; ELECTROMAGNETIC RADIATION; ELEMENTARY PARTICLES; FERMIONS; HADRONS; IONIZING RADIATIONS; MEASURING INSTRUMENTS; MEDICINE; NEUTRONS; NUCLEAR MEDICINE; NUCLEONS; PHOTONUCLEONS; PHOTOTUBES; RADIATION DETECTORS; RADIATIONS; RADIOLOGY; SCINTILLATION COUNTERS; SEMICONDUCTOR DEVICES; SOLID SCINTILLATION DETECTORS; THERAPY
Optional Information
- Copyright