Purpose: Due to significant measuring inaccuracies that can occur under certain conditions, the use of electronic personal dosimeters in statutory measurements in X-ray diagnostics is currently legally restricted. The present study investigates the clinically relevant situations in which measurement errors of more then 20 % can be anticipated. Materials and Methods: Four series of experiments were made, comparing the results of the electronic personal dosimeter EPD Mk2.3 to those of reference dosimeters (TLDs and diagnostic dosimeters). On the one hand, personal doses have been determined in the routine operation of controlled areas in various departments. On the other hand, measurements on phantoms have been conducted in extreme but realistic situations under radiation protection. Experiments were conducted in unweakened scattered radiation as well as in unattenuated and attenuated direct radiation. Results: The tested electronic personal dosimeter type meets the requirements regarding measurement accuracy for 'official' personal dosimeters in all of the examined clinically relevant scattered radiation fields. Only if exposed to radiation directly, an underestimation of the dose can occur and can be greater than 90 %. Conclusion: In the range of scattered radiation of diagnostic X-ray equipment, even in pulsed fields, the use of electronic personal dosimeters is reasonable. Considerable measurement errors can only arise in radiation fields that are not realistic under regular conditions and even in connection with most accidents. (orig.)

Additional details

Additional titles

Original title (German)
Sind elektronische Personendosimeter in klinischen Expositionssituationen grundsaetzlich nicht einsetzbar?

Publishing Information

Journal Title
RoeFo - Fortschritte auf dem Gebiete der Roentgenstrahlen und der bildgebenden Verfahren
Journal Volume
182
Journal Issue
9
Journal Page Range
p. 773-779
ISSN
1438-9029
CODEN
RFGNDO

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
42082381
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
DOSIMETRY; ELECTRON DOSIMETRY; OCCUPATIONAL DISEASES; OCCUPATIONAL EXPOSURE; OCCUPATIONAL SAFETY
Descriptors DEC
DISEASES; DOSIMETRY; SAFETY