Published February 1980 | Version v1
Report Open

Oxygen-hydrogen meter assembly for use in remote sodium sampling systems

Description

An assembly of an electrolytic oxygen meter and a diffusion type hydrogen meter was designed to fit into the Multipurpose Sampler hardware already installed and operating on the four FFTF sodium systems. One of the key elements in this assembly is a ceramic-metal sealed oxygen sensor which allows use of a metal tube to extend the 51 cm (20 in.) between the sampler top and the flowing sodium region

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

11566077.pdf

Files (334.1 kB)

Name Size Download all
md5:e997f5616cd99112306af9d9dcc44d14
334.1 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
8 p.
Report number
HEDL-SA--1893-FP

Conference

Title
2. international conference of liquid metal technology for energy systems.
Dates
20 - 24 Apr 1980.
Place
Richland, WA, USA.

Optional Information

Secondary number(s)
CONF-800401--18.