Published March 2015 | Version v1
Report Restricted

Design of long neutron counter for intensified D-T neutron source

  • 1. Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui (China)

Description

A low sensitivity long neutron counter was designed as a standard directional flow detector to monitor neutron fluence reference values of an accelerator-based 14 MeV D-T neutron source with yield about 1013 n/s. The energy response over 6 MeV was improved using a tungsten radiator, which acts as an energy converter via the (n, xn) reaction. Different parameters were optimized to flatten the neutron energy response over a wide energy range. A simulation of the designed long neutron counter using the Monte Carlo codes MCNP was undergone. The response function is relatively flat in the energy range of 1 keV-20 MeV. The results show the maximal relative variation is about 7.8%. (author)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Part of:
Proceedings of the international conference on physics of reactors (PHYSOR2014)

Additional details

Identifiers

Publishing Information

Imprint Title
Proceedings of the international conference on physics of reactors (PHYSOR2014)
Imprint Pagination
5489 p.
Journal Page Range
5 p.
Report number
JAEA-Conf--2014-003

Conference

Title
International conference on physics of reactors
Acronym
PHYSOR2014
Dates
28 Sep - 3 Oct 2014
Place
Kyoto (Japan)

Optional Information

Notes
Available as CD-ROM Data in PDF format, Folder Name: PAPERS, Paper ID: a11_1126839.pdf; 15 refs., 2 figs., 2 tabs.