Prospective ECG triggering reduces prosthetic heart valve-induced artefacts compared with retrospective ECG gating on 256-slice CT
Creators
- 1. Academic Medical Center, Department of Cardiothoracic Surgery, Amsterdam (Netherlands)
- 2. University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands)
- 3. University Medical Center Utrecht, Department of Biostatistics, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands)
- 4. University of Technology Eindhoven, Department of Biomedical Engineering, Eindhoven (Netherlands)
- 5. Radboud University Nijmegen Medical Center, Department of Radiology, Nijmegen (Netherlands)
Description
Multidetector computed tomography (MDCT) has diagnostic value for the evaluation of prosthetic heart valve (PHV) dysfunction but it is hampered by artefacts. We hypothesised that image acquisition using prospective triggering instead of retrospective gating would reduce artefacts related to pulsating PHV. In a pulsatile in vitro model, a mono- and bileaflet PHV were imaged using 256 MDCT at 60, 75 and 90 beats per minute (BPM) with either retrospective gating (120 kV, 600 mAs, pitch 0.2, CTDIvol 39.8 mGy) or prospective triggering (120 kV, 200 mAs, CTDIvol 13.3 mGy). Two thresholds (>175 and <-45HU), derived from the density of surrounding structures, were used for quantification of hyper- and hypodense artefacts. Image noise and artefacts were compared between protocols. Prospective triggering reduced hyperdense artefacts for both valves at every BPM (P = 0.001 all comparisons). Hypodense artefacts were reduced for the monoleaflet valve at 60 (P = 0.009), 75 (P = 0.016) and 90 BPM (P = 0.001), and for the bileaflet valves at 60 (P = 0.001), 90 (P = 0.001) but not at 75 BPM (P = 0.6). Prospective triggering reduced image noise at 60 (P = 0.001) and 75 (P < 0.03) but not at 90 BPM. Compared with retrospective gating, prospective triggering reduced most artefacts related to pulsating PHV in vitro. circle Computed tomographic images are often degraded by prosthetic heart valve-induced artefacts circle Prospective triggering reduces prosthetic heart valve-induced artefacts in vitro circle Artefact reduction at 90 beats per minute occurs without image noise reduction circle Prospective triggering may improve CT image quality of moving hyperdense structures. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-011-2358-1Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 22
- Journal Issue
- 6
- Journal Page Range
- p. 1271-1277
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 43071173
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CARDIOVASCULAR SYSTEM; COMPUTERIZED TOMOGRAPHY; DENSITY; DIAGNOSIS; ELECTROCARDIOGRAMS; ERRORS; IMAGE PROCESSING; IN VITRO; MECHANICAL HEART; NOISE; PHANTOMS; PROSTHESES; SURGICAL MATERIALS; VALVES
- Descriptors DEC
- ARTIFICIAL ORGANS; CONTROL EQUIPMENT; DIAGNOSTIC TECHNIQUES; DIAGRAMS; EQUIPMENT; FLOW REGULATORS; INFORMATION; MATERIALS; MEDICAL SUPPLIES; MOCKUP; PHYSICAL PROPERTIES; PROCESSING; PROSTHESES; STRUCTURAL MODELS; TOMOGRAPHY