Published October 2017 | Version v1
Journal article

Adaption of a PIN-diode detector as an online neutron monitor for the thermal column of the TRIGA research reactor

  • 1. Institut für Kernchemie, Johannes Gutenberg-Universität, Mainz DE-55128 (Germany)
  • 2. Center of Health & Bioresources, AIT Austrian Institute of Technology, Donau-City-Strasse 1/2, A-1220 Vienna (Austria)

Description

A BNCT online neutron monitoring system was tested in a TRIGA reactor, using a silicon PIN-diode with a conversion foil. The setup was tested with different reactor powers at the hot and cold ends of the irradiation channel, using activation foils to compare with measured fluxes. The results demonstrate good reproducibility and show a linear correlation between signal of the PIN-diode and neutron flux at all positions, demonstrating this approach to be suitable for online monitoring of the neutron flux. - Highlights: • A silicon PIN-diode with a conversion foil was tested for online neutron monitoring. • The system was evaluated for different reactor powers and irradiation sites. • The results show a linear correlation of the PIN-diode's signal with neutron flux.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2017.07.010

Additional details

Identifiers

DOI
10.1016/j.apradiso.2017.07.010;
PII
S0969-8043(17)30066-0;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
128
Journal Page Range
p. 142-147
ISSN
0969-8043
CODEN
ARISEF

Optional Information

Copyright
Copyright (c) 2017 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.