Published February 1991 | Version v1
Report Open

Preparation of rT3 in human serum ria kit

  • 1. Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy

Description

A method for the measurement of rT3 in serum by radioimmunoassay is presented. The double antibody plus polyethylene glycol was used as separating reagent. The method is simple, precise and sensitive. Serum rT3 values of normal (n = 61) were 47.7 ± 11.34 x 10-8 g/L (X-bar ± SD). Patients with hyperthyroidism (n = 8) serum rT3 values were 272.2 ± 91.1 x 10-8 g/L (X-bar ± SD) and patients with hypothyroidism (n = 2) serum rT3 values were 11.4 ± 8.3 x 10-8 g/L (X-bar ± SD). It appears to be a useful diagnostic procedure for thyroid diseases

Availability note (English)

MF available from INIS under the Report Number.

Files

23074174.pdf

Files (252.4 kB)

Name Size Download all
md5:aad0d3aa69536be967d5e62bc73ea210
252.4 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
9 p.
Report number
CNIC--00471

Optional Information

Secondary number(s)
IAE--0090.