Description

A forced outage due to a steam generator tube leak in a Korean nuclear power plant has been reported . Primary water stress corrosion cracking has occurred in many tubes in the plant, and they were repaired using sleeves or plugs. In order to develop proper repair criteria, it is necessary to understand the leak behavior of the tubes containing stress corrosion cracks. Cracked specimens were prepared using a room temperature cracking technique, and the leak rates and burst pressures of the degraded tubes were determined both at room temperature and at a high temperature. Some tubes with 100% through wall cracks did not show a leakage at 10.8 MPa, which is the typical pressure difference of the pressurized water reactors (PWRs) during a normal operation. In some tests, the leak rates of the tubes increased with time at a constant pressure. In a high temperature pressure test at 282 deg. C one specimen showed a very small leakage at 18.6 MPa, which stopped after a small increase in the test pressure. Because stress corrosion cracks can develop at relatively low stresses, even 100% through wall cracks can be so tight that they will not leak at a normal operating pressure

Additional details

Identifiers

DOI
10.1016/j.nucengdes.2005.06.013;
PII
S0029-5493(05)00238-4;

Publishing Information

Journal Title
Nuclear Engineering and Design
Journal Volume
235
Journal Issue
23
Journal Page Range
p. 2477-2484
ISSN
0029-5493
CODEN
NEDEAU

Optional Information

Copyright
Copyright (c) 2005 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.