Postmortem metallurgical examination of a fire-exposed spent fuel shipping cask

Description

A potmortem examination of a large fire-exposed rail-transported spent fuel shipping container has revealed the presence of two macrofissures in the outer cask shell. The first, a part-thru crack located within the seam weld fusion zone of the outer cask shell, was typical of hot cracks that may be found in stainless steel weldments. The second, located within the stainless steel base metal, apparently originated at microcracks formed during the welding of a copper-stainless steel dissimilar metal joint. The latter microcrack then propagated during the fire-test, ultimately penetrating the outer shall of the cask. 18 figures, 2 tables

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.

Files

11552726.pdf

Files (417.7 kB)

Name Size Download all
md5:c33b33e5c2b1bdb2e97675f9486e0d54
417.7 kB Preview Download

Additional details

Additional titles

Augmented title (English)
After impact test

Publishing Information

Imprint Pagination
35 p.
Report number
SAND--79-1424