Development of a new electronic neutron imaging system

  • 1. Department of Mechanical, Aerospace and Nuclear Engineering, Thornton Hall, University of Virginia, Charlottesville, VA 22903-2442 (United States)
  • 2. Industrial Quality, Inc., Gaithersburg, MD (United States)
  • 3. Paultek Systems, Inc., Nevada City, CA (United States)
  • 4. Naval Air Warfare Center, China Lake, CA (United States)

Description

An electronic neutron imaging camera system was developed for use with thermal, epithermal, and fast neutrons in applications that include nondestructive inspection of explosives, corrosion, turbine blades, electronics, low Z components, etc. The neutron images are expected to provide information to supplement that available from X-ray tests. The primary camera image area was a 30x30 cm field-of-view with a spatial resolution approaching 1.6 line pairs/mm (lp/mm). The camera had a remotely changeable second lens to limit the field-of-view to 7.6x7.6 cm for high spatial resolution (at least 4 lp/mm) thermal neutron imaging, but neutron and light scatter will limit resolution for fast neutrons to about 0.5 lp/mm. Remote focus capability enhanced camera set-up for optimum operation. The 75 dB dynamic range camera system included 6Li-based screens for imaging of thermal and epithermal neutrons and ZnS(Ag)-based screens for fast neutron imaging. The fast optics was input to a Super S-25 Gen II image intensifier, fiber optically coupled to a 1134 (h)x486 (v) frame transfer CCD camera. The camera system was designed to be compatible with a Navy-sponsored accelerator neutron source. The planned neutron source is an RF quadrupole accelerator that will provide a fast neutron flux of 107 n/cm2-s (at a source distance of 1 m) at an energy of about 2.2 MeV and a thermal neutron flux of 106 n/cm2-s at a source L/D ratio of 30. The electronic camera produced good quality real-time images at these neutron levels. On-chip integration could be used to improve image quality for low flux situations. The camera and accelerator combination provided a useful non-reactor neutron inspection system

Additional details

Identifiers

PII
S0168900298012947;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
424
Journal Issue
1
Journal Page Range
p. 9-14
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 1999 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.