Published July 1, 2013 | Version v1
Journal article

Sub-nanosecond clock synchronization and trigger management in the nuclear physics experiment AGATA

  • 1. Istituto Nazionale di Fisica Nucleare - Sez. di Padova, Via Marzolo 8, 35128 Padova (Italy)
  • 2. Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali di Legnaro, Viale dell'Università 2, 35020 Legnaro (PD) (Italy)
  • 3. Maison de la Simulation (MDLS), bât. 565, CEA Saclay, 91191 Gif-sur-Yvette cedex (France)
  • 4. University of West Scotland, School of Engineering High Street, PA1 2BE Paisley (United Kingdom)
  • 5. Università degli Studi di Padova - Dipartimento di Fisica Via Marzolo 8, 35128 Padova (Italy)

Description

The new-generation spectrometer AGATA, the Advanced GAmma Tracking Array, requires sub-nanosecond clock synchronization among readout and front-end electronics modules that may lie hundred meters apart. We call GTS (Global Trigger and Synchronization System) the infrastructure responsible for precise clock synchronization and for the trigger management of AGATA. It is made of a central trigger processor and nodes, connected in a tree structure by means of optical fibers operated at 2Gb/s. The GTS tree handles the synchronization and the trigger data flow, whereas the trigger processor analyses and eventually validates the trigger primitives centrally. Sub-nanosecond synchronization is achieved by measuring two different types of round-trip times and by automatically correcting for phase-shift differences. For a tree of depth two, the peak-to-peak clock jitter at each leaf is 70 ps; the mean phase difference is 180 ps, while the standard deviation over such phase difference, namely the phase equalization repeatability, is 20 ps. The GTS system has run flawlessly for the two-year long AGATA campaign, held at the INFN Legnaro National Laboratories, Italy, where five triple clusters of the AGATA sub-array were coupled with a variety of ancillary detectors

Availability note (English)

Available from http://dx.doi.org/10.1088/1748-0221/8/07/P07003

Additional details

Publishing Information

Journal Title
Journal of Instrumentation
Journal Volume
8
Journal Issue
07
Journal Page Range
p. P07003
ISSN
1748-0221

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
44078521
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
NUCLEAR PHYSICS; OPTICAL FIBERS; PHASE SHIFT; READOUT SYSTEMS; SPECTROMETERS; SYNCHRONIZATION
Descriptors DEC
FIBERS; MEASURING INSTRUMENTS; PHYSICS