Published April 1990 | Version v1
Journal article

Peripheral doses of two linear accelerators employing universal wedges

  • 1. Cancer Control Agency of British Columbia, Victoria Cancer Clinic, Victoria, British Columbia (Canada). Div. of Radiation Physics

Description

This note describes a series of basic measurements performed to characterize the effects of a universal wedge upon the peripheral dose. Peripheral dose profiles were obtained for open and wedged fields for two linear accelerators using universal wedges and generating 6 MV and 10 MV X rays. The peripheral dose is presented as a percentage of the central axis maximum and as a function of field dimension, wedge orientation and distance from the geometric field edge. (UK)

Additional details

Publishing Information

Journal Title
British Journal of Radiology
Journal Volume
63
Journal Issue
748
Series
Br. J. Radiol.
Journal Page Range
295-298
ISSN
0007-1285
CODEN
BJRAA

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
21067859
Subject category
S07: ISOTOPES AND RADIATION SOURCES;
Descriptors DEI
BEAM SHAPING; COLLIMATORS; LINEAR ACCELERATORS; MEV RANGE 01-10; RADIOTHERAPY; SPATIAL DOSE DISTRIBUTIONS
Descriptors DEC
ACCELERATORS; DISTRIBUTION; ENERGY RANGE; MEDICINE; MEV RANGE; RADIATION DOSE DISTRIBUTIONS; SPATIAL DISTRIBUTION; THERAPY