Published November 15, 1975 | Version v1
Journal article

A 50 MeV polarised neutron facility incorporating a high pressure tritium gas target

  • 1. California Univ., Davis (USA). Crocker Nuclear Lab.
  • 2. Los Alamos Scientific Lab., N.Mex. (USA)

Description

A collimated beam of 50 MeV neutrons with a polarization of 0.46+-0.02 and a flux of approximately 104n/cm2s at 3 m is produced via the T(d,n(pol))4He reaction. Beams up to 20 μA of 38 MeV deuterons are directed through a liquid nitrogen cooled, pressurized (5.5 atm) tritium target. Details of the design, construction, and operation of the neutron facility are presented. The procedures for transferring the tritium to and from the target are also discussed as well as several safety features. (Auth.)

Additional details

Identifiers

Publishing Information

Journal Title
Nuclear Instruments and Methods
Journal Volume
129
Journal Issue
2
Series
Nucl. Instrum. Methods.
Journal Page Range
345-352
ISSN
0029-554X

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent