Published March 1988 | Version v1
Journal article

Attachment of membrane separator for removal of radon to ionization chamber installed for tritium stack monitor

  • 1. Nagoya Univ. (Japan). Faculty of Engineering

Description

The effect of background counts induced by α-particles mainly from Rn in air was removed by the attachment of a water-permselective membrane separator to a tritium stack monitor equipped previously. Water vapor, after permeating the membrane selectively, was carried by N2 gas into an ionization chamber where the activity of tritium was measured. The consumption of N2 gas for carrier was reduced by recycling the gas through dehumidification processes; (1) condensation by pressure, (2) condensation by refrigeration and (3) adsorption (by adsorbents), so that there is no added daily work arising from the attachment for maintenance of the tritium monitor. (author)

Additional details

Publishing Information

Journal Title
J. Nucl. Sci. Technol. (Tokyo)
Journal Volume
25
Journal Issue
3
Series
J. Nucl. Sci. Technol. (Tokyo).
Journal Page Range
289-294
ISSN
0022-3131
CODEN
JNSTA