Technique factors and their relationship to radiation dose in pendant geometry breast CT
Creators
- 1. Department of Radiology , University of California San Diego, La Jolla, California (United States)
- 2. Department of Radiology, University of California Davis Medical Center, Sacramento, California (United States)
Description
The use of breast computed tomography (CT) as an alternative to mammography in some patients is being studied at several institutions. However, the radiation dosimetry issues associated with breast CT are markedly different than in the case of mammography. In this study, the spectral properties of an operational breast CT scanner were characterized both by physical measurement and computer modeling of the kVp-dependent spectra, from 40 to 110 kVp (Be window W anode with 0.30 mm added Cu filtration). Previously reported conversion factors, normalized glandular dose for CT-DgN(ct), derived from Monte Carlo methods, were used in concert with the output spectra of the breast scanner to compute the mean glandular dose to the breast based upon different combinations of x-ray technique factors (kVp and mAs). The mean glandular dose (MGD) was measured as a function of the compressed breast thickness (2-8 cm) and three different breast compositions (0%, 50%, and 100% glandular fractions) in four clinical mammography systems in our institution. The average MGD from these four systems was used to compute the technique factors for breast CT systems that would match the two-view mammographic dose levels. For a 14 cm diameter breast (equivalent to a 5 cm thick compressed breast in mammography), air kerma levels at the breast CT scanner's isocenter (468 mm from the source) of 4.4, 6.4, and 9.0 mGy were found to deliver equivalent mammography doses for 0%, 50%, and 100% glandular breasts (respectively) at 80 kVp. At 80 kVp (where air kerma was 11.3 mGy/100 mAs at the isocenter), 57 mAs (integrated over the entire scan) was required to match the mammography dose for a 14 cm 50% glandular breast. At 50 kVp, 360 mAs is required to match mammographic dose levels. Tables are provided for both air kerma at the isocenter and mAs for 0%, 50%, and 100% glandular breasts. Other issues that impact breast CT technique factors are also discussed
Additional details
Identifiers
- DOI
- 10.1118/1.2128126;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 32
- Journal Issue
- 12
- Journal Page Range
- p. 3767-3776
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 37038320
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE; S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; COMPUTERIZED TOMOGRAPHY; DOSIMETRY; KERMA; MAMMARY GLANDS; MONTE CARLO METHOD; PATIENTS; RADIATION DOSES; X RADIATION
- Descriptors DEC
- BODY; CALCULATION METHODS; DIAGNOSTIC TECHNIQUES; DOSES; ELECTROMAGNETIC RADIATION; GLANDS; IONIZING RADIATIONS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIATIONS; RADIOLOGY; TOMOGRAPHY