Published May 2013
| Version v1
Journal article
Confirmation of the seismic resistance of nuclear power plant equipment after assembly
- 1. JSC "Atomtehenergo" (Russian Federation)
Description
It is shown that the natural frequencies and damping decrements of nuclear power plant equipment can only be determined experimentally and directly at the power generation units (reactors) of nuclear power plants under real disassembly conditions for the equipment, piping network, thermal insulation, etc. A computational experimental method is described in which the natural frequencies and damping decrements are determined in the field and the seismic resistance is reevaluated using these values. This method is the basis of the standards document "Methods for confirming the dynamic characteristics of systems and components of the generating units of nuclear power plants which are important for safety" prepared and introduced in 2012.
Additional details
Identifiers
Publishing Information
- Journal Title
- Power Technology and Engineering (Print)
- Journal Volume
- 47
- Journal Issue
- 1
- Journal Page Range
- p. 42-46
- ISSN
- 1570-145X
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 44081577
- Subject category
- S42: ENGINEERING; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Standard or Specification
- Descriptors DEI
- EQUIPMENT; FREQUENCY MEASUREMENT; NUCLEAR POWER PLANTS; PIPES; POWER TRANSMISSION LINES; SEISMIC ISOLATION; SEISMIC WAVES; STANDARDS DOCUMENT; THERMAL INSULATION
- Descriptors DEC
- NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS; TUBES
Optional Information
- Copyright
- Copyright (c) 2013 Springer Science+Business Media New York
- Notes
- http://www.springer-ny.com