Published January 2016 | Version v1
Journal article

Measurement of void fraction in bubbly-slug flow with a constant electric current method

  • 1. Univ. of Tsukuba, Dept. of Engineering Mechanics and Energy, Tsukuba, Ibaraki (Japan)

Description

In several void fraction measurement methods, a constant electric current method which is one of conductance methods is focused in the present study. By using this method, void fraction can be measured with higher temporal resolution. However, it has been mainly applied to annular flow in previous studies. In the present study, Maxwell's estimation, Bruggemann's estimation, low void fraction approximation and new estimations which consider the bubble shape are applied in order to measure more accurately void fraction of dispersed bubbly flow and slug flow. To understand the effect of bubble shapes and flow patterns, void fraction was measured by the constant electric current method for a rising single spherical bubble and a rising single slug bubble without a forced convection. In addition, void fraction was also measured in bubbly flow and bubbly-slug flow with a forced convection. Then, effects of flow patterns on the proposed estimations of void fraction and the accuracy of their estimations were discussed with the measurement results. From the result, the new estimations which consider a bubble shape are more accurate than the previous estimation in a slug bubble and bubbly-slug flow. (author)

Availability note (English)

Available from http://dx.doi.org/10.1080/00223131.2015.1021284

Additional details

Publishing Information

Journal Title
Journal of Nuclear Science and Technology (Tokyo)
Journal Volume
53
Journal Issue
1
Journal Page Range
p. 48-60
ISSN
0022-3131

Optional Information

Notes
15 refs., 15 figs.