Published 2017 | Version v1
Conference paper

Pressure drop for gas-liquid two-phase annular flow across grid spacer with mixing vane in vertical circular pipe

  • 1. Kumamoto Univ., Kumamoto (Japan)

Description

This study investigates the effects of mixing vane (MV) attached to a grid spacer on pressure drop for air-water annular flows in a vertical circular pipe of 16 mm I.D. In order to know the effects of MV, grid spacers with or without MV were installed in the test pipe. Three types of grid spacers with MV which has four MVs inclined 20, 30 degree from the vertical flow axis (4-MV20, 4-MV30) and two MVs inclined 30 degree (2-MV30) were used. In addition, two liquid injection methods (wall and center jet injections) are adopted to control liquid droplet entrainment faction in gas core. In the experiment, pressure drop along the channel upstream and downstream from the spacer was measured with a pressure transducer. In the analysis, the correlation of the pressure drop across the spacer is newly developed based on the present data. (author)

Part of:
Proceedings of the 22nd national symposium on power and energy systems (SPES 2017)

Additional details

Additional titles

Original title (Japanese)
垂直円管内の混合翼付きグリッドスペーサーを通過する気液二相環状流の圧力損失

Publishing Information

Imprint Title
Proceedings of the 22nd national symposium on power and energy systems (SPES 2017)
Imprint Pagination
4 p.

Conference

Title
22. national symposium on power and energy systems
Acronym
SPES 2017
Dates
14-15 Jun 2017
Place
Toyohashi, Aichi (Japan)

Optional Information

Notes
Available as USB Flash Memory Card in PDF format, Folder Name: pdf; Paper ID: B221.pdf; 4 refs., 9 figs. Imprint:#7B2C#22#56DE##52D5##529B##30FB##30A8##30CD##30EB##30AE##30FC##6280##8853##30B7##30F3##30DD##30B8##30A6##30E0##8B1B##6F14##8AD6##6587##96C6#