Resistive wall wakefield in the LCLS undulator beam pipe
Description
We have shown that, due to the ac resistive wall wakefield, the present LCLS undulator design, with its round copper beam pipe, will result in an unacceptably large energy variation induced within the bunch over the length of the undulator (0.6%). If, instead, we use a flat, aluminum chamber, the energy variation can be reduced to within acceptable limits (less-than-or-similar-to 0.2%). Finally we have shown that the effect of the anomalous skin effect in the beam pipe wall is small, and can be ignored
Availability note (English)
Available from PURL: https://www.osti.gov/servlets/purl/833045-eZvzGG/native/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- [vp.]
- Report number
- SLAC-PUB--10707
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 36011233
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- ALUMINIUM; COPPER; DESIGN; SKIN EFFECT; WIGGLER MAGNETS
- Descriptors DEC
- ELEMENTS; EQUIPMENT; MAGNETS; METALS; TRANSITION ELEMENTS
Optional Information
- Contract/Grant/Project number
- AC--03-76SF00515
- Funding organization
- USDOE Office of Science (United States)