Published September 1, 2020 | Version v1
Journal article

Calibrating stereo-digital image correlation system using synthetic speckle-pattern calibration target

  • 1. Institute of Solid Mechanics, School of Aeronautic Science and Engineering, Beihang University, Beijing 100191 (China)
  • 2. College of Aerospace Science and Engineering, National University of Defense Technology, Changsha 410073 (China)

Description

We describe an alternative stereo calibration method for stereo-digital image correlation (stereo-DIC) using computer-simulated speckle-pattern calibration targets and a DIC-based control points matching technique. The present work refines and extends the recently proposed camera calibration method to stereo calibration, which is an essential part of stereo-DIC measurement. In the proposed calibration method, the calibration target is generated by displaying a synthetic speckle pattern on a commercial tablet. On the simulated speckle pattern, a group of control points is specified with flexible location and number, which is further precisely matched to the captured calibration images using the well-developed subset-based DIC algorithm. These precisely matched control points are subsequently used to calibrate the intrinsic and extrinsic parameters of the stereo-DIC system with stereo calibration algorithm. For better accuracy, the error in the manufacture of the calibration target is also considered and compensated. As a flexible number of control point matches are registered with high accuracy and strong robustness, the presented stereo calibration method using synthetic speckle pattern calibration target offers higher calibration accuracy than that based on a calibration target with a limited number of designated features, such as checkerboard target and circular point target. After being demonstrated by a set of simulated calibration tests, the proposed stereo calibration method was applied to calibrate a real stereo-DIC system, which was then used to measure 3D full-field shapes and displacements. The results confirm the effectiveness and accuracy of the proposed stereo calibration method for stereo-DIC applications. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1361-6501/ab8dfb

Additional details

Identifiers

Publishing Information

Journal Title
Measurement Science and Technology
Journal Volume
31
Journal Issue
9
Journal Page Range
[12 p.]
ISSN
0957-0233
CODEN
MSTCEP

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
52117728
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Descriptors DEI
ACCURACY; ALGORITHMS; CALIBRATION; COMPUTERIZED SIMULATION; CONTROL; ERRORS
Descriptors DEC
MATHEMATICAL LOGIC; SIMULATION