Published 1988 | Version v1
Miscellaneous

Preparation of Tc-99m human serum albumin using stannous citrate and stannous chloride

Description

99mTc-albumin is widely used as radioactive indicator in the measurement of cardiac output by external counting techniques and in blood volume studies. The quality of 99mTc-albumin depends on the method of preparation. A comparative study had been carried out on the 99mTc-albumin preparation by the stannous chloride, stannous tartarate and stannous citrate method. The different parameters investigated for each method include: pH, albumin concentration, reductant concentration and ascorbic acid as antioxidant stabilizer. The biological distribution of 99mTc-albumin, prepared by different methods, were determined in mice and rats. A procedure was developed for the preparation of stannous human serum albumin (HSA) kit for human application the kit provides a freeze dried sterile formulation for reconstitution with sterile 99mTc pertechnetate solution to give 99mTc-Hsa, the effect of irradiation sterilization on the freeze dried kit was studied by spectrophotometric determination and biological distribution in mice and rats

Additional details

Publishing Information

Publisher
Egyptian Society of Nuclear Sciences and Applications.
Imprint Place
Cairo (Egypt)
Imprint Title
Proceedings of the fourth Conference on Nuclear Sciences and Applications. Vol. 2
Imprint Pagination
426 p.
Journal Page Range
p. 590-597.
Report number
INIS-mf--12745

Conference

Title
4. Conference of Nuclear Sciences and Applications.
Dates
6-10 Mar 1988.
Place
Cairo (Egypt).