Published November 1, 2014 | Version v1
Journal article

Laser-induced breakdown spectroscopy for in situ qualitative and quantitative analysis of mineral ores

  • 1. Institute of Physical Engineering, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 61669 Brno (Czech Republic)
  • 2. BAM, Federal Institute for Materials Research and Testing, Richard Willstätter-Straße 11, D-12489 Berlin (Germany)
  • 3. Institute for Mining, Technical University Clausthal, Erzstraße 18, 38678 Clausthal-Zellerfeld (Germany)
  • 4. Chemistry Department, Humboldt Univerisät zu Berlin, Brook-Taylor-Straße 2, D-12489 Berlin (Germany)

Description

In this work, the potential of laser-induced breakdown spectroscopy (LIBS) for discrimination and analysis of geological materials was examined. The research was focused on classification of mineral ores using their LIBS spectra prior to quantitative determination of copper. Quantitative analysis is not a trivial task in LIBS measurement because intensities of emission lines in laser-induced plasmas (LIP) are strongly affected by the sample matrix (matrix effect). To circumvent this effect, typically matrix-matched standards are used to obtain matrix-dependent calibration curves. If the sample set consists of a mixture of different matrices, even in this approach, the corresponding matrix has to be known prior to the downstream data analysis. For this categorization, the multielemental character of LIBS spectra can be of help. In this contribution, a principal component analysis (PCA) was employed on the measured data set to discriminate individual rocks as individual matrices against each other according to their overall elemental composition. Twenty-seven igneous rock samples were analyzed in the form of fine dust, classified and subsequently quantitatively analyzed. Two different LIBS setups in two laboratories were used to prove the reproducibility of classification and quantification. A superposition of partial calibration plots constructed from the individual clustered data displayed a large improvement in precision and accuracy compared to the calibration plot constructed from all ore samples. The classification of mineral samples with complex matrices can thus be recommended prior to LIBS system calibration and quantitative analysis. - Highlights: • Twenty seven igneous rocks were measured on different LIBS systems. • Principal component analysis (PCA) was employed for classification. • The necessity of the classification of the rock (ore) samples prior to the quantification analysis is stressed. • Classification based on the whole LIP spectra and the selected regions of interest, matrix elements, was compared

Availability note (English)

Available from http://dx.doi.org/10.1016/j.sab.2014.08.027

Additional details

Identifiers

DOI
10.1016/j.sab.2014.08.027;
PII
S0584-8547(14)00202-X;

Publishing Information

Journal Title
Spectrochimica Acta. Part B, Atomic Spectroscopy
Journal Volume
101
Journal Page Range
p. 155-163
ISSN
0584-8547
CODEN
SAASBH

Optional Information

Copyright
Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.