Published June 1987 | Version v1
Report

Intergranular SCC of Alloy 600 in primary side PWR environments

  • 1. The Ohio State Univ., Columbus

Description

Initial experiments on intergranular stress corrosion cracking of Alloy 600 in a solution of H3BO3 + LiOH, simulating primary water environments, are described. Slow strain rate tests (7.3 x 10-7/s) were conducted to evaluate the role of hydrogen present in the environment or generated by the corrosion reaction. Tests were run in a specially designed high pressure recirculating loop at 3000C. Galvanostatic charging was used to promote the entry of hydrogen into the alloy

Additional details

Publishing Information

Imprint Title
Proceedings: 1985 workshop on primary-side stress corrosion cracking of PWR steam generator tubing
Journal Page Range
p. 28.1-28.17.
Report number
EPRI-NP--5158

Conference

Title
Workshop on primary-side stress corrosion cracking of PWR steam generator tubing.
Dates
20-22 Mar 1985.
Place