Published April 7, 1987 | Version v1
Report Restricted

Melter feed system 3-way feed valve Auma motorized operator

Description

This document discusses the Scale Melter currently testing feed systems. One component of that system is a valve operator, which directs the feed slurry or flush water through the 3-way ball valve to the melter. This valve operator may be causing problems on the TNX Scale Melter by failing to accurately align the feed valve ports

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE92015108; NTIS; INIS; US Govt. Printing Office Dep.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
5 p.
Report number
DPST--87-235

Optional Information

Contract/Grant/Project number
Contract AC09-76SR00001; AC09-89SR18035
Funding organization
USDOE, Washington, DC (United States).