Validation of internal dosimetry protocols based on stochastic method
Creators
- 1. Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)
- 2. Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear
Description
Computational phantoms adapted to Monte Carlo codes have been applied successfully in radiation dosimetry fields. NRI research group has been developing Internal Dosimetry Protocols - IDPs, addressing distinct methodologies, software and computational human-simulators, to perform internal dosimetry, especially for new radiopharmaceuticals. Validation of the IDPs is critical to ensure the reliability of the simulations results. Inter comparisons of data from literature with those produced by our IDPs is a suitable method for validation. The aim of this study was to validate the IDPs following such inter comparison procedure. The Golem phantom has been reconfigured to run on MCNP5. The specific absorbed fractions (SAF) for photon at 30, 100 and 1000 keV energies were simulated based on the IDPs and compared with reference values (RV) published by Zankl and Petoussi-Henss, 1998. The SAF average differences from RV and those obtained in IDP simulations was 2.3 %. The SAF largest differences were found in situations involving low energy photons at 30 keV. The Adrenals and thyroid, i.e. the lowest mass organs, had the highest SAF discrepancies towards RV as 7.2 % and 3.8 %, respectively. The statistic differences of SAF applying our IDPs from reference values were considered acceptable at the 30, 100 and 1000 keV spectra. We believe that the main reason for the discrepancies in IDPs run, found in lower masses organs, was due to our source definition methodology. Improvements of source spatial distribution in the voxels may provide outputs more consistent with reference values for lower masses organs. (author)
Files
47006373.pdf
Files
(668.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:ba6fbfd45642617113ccf4621a1f3e04
|
668.6 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 10 p.
- Report number
- INIS-BR--15744
Conference
- Title
- international nuclear atlantic conference. Brazilian nuclear program. State policy for a sustainable world; 12. ENAN: meeting on nuclear applications
- Acronym
- INAC 2015
- Dates
- 4-9 Oct 2015
- Place
- Sao Paulo, SP (Brazil)
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 47006373
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ABSORBED RADIATION DOSES; COMPUTERIZED SIMULATION; DOSIMETRY; MONTE CARLO METHOD; NEUTRON TRANSPORT; PHANTOMS; PHOTONS; RECOMMENDATIONS; SPATIAL DOSE DISTRIBUTIONS; STOCHASTIC PROCESSES
- Descriptors DEC
- BOSONS; CALCULATION METHODS; DOSES; ELEMENTARY PARTICLES; MASSLESS PARTICLES; MOCKUP; NEUTRAL-PARTICLE TRANSPORT; RADIATION DOSE DISTRIBUTIONS; RADIATION DOSES; RADIATION TRANSPORT; SIMULATION; STRUCTURAL MODELS