Comparison of machine learning-based CT fractional flow reserve with cardiac MR perfusion mapping for ischemia diagnosis in stable coronary artery disease
Creators
- 1. Department of Radiology, Shanghai Geriatric Medical Center, 2560 Chunshen Road, Minhang District, 201104, Shanghai (China)
- 2. Department of Radiology, Zhongshan Hospital, Fudan University, No. 180 Fenglin Road, 200032, Shanghai (China)
- 3. School of Basic Medical Sciences, Fudan University, 200032, Shanghai (China)
- 4. Department of Cardiology, Zhongshan Hospital, Fudan University, 200032, Shanghai (China)
- 5. Department of Vascular Surgery, Zhongshan Hospital, Fudan University, 200032, Shanghai (China)
- 6. Siemens Healthineers China, Shanghai (China)
Description
To compare the diagnostic performance of machine learning (ML)-based computed tomography-derived fractional flow reserve (CT-FFR) and cardiac magnetic resonance (MR) perfusion mapping for functional assessment of coronary stenosis. Between October 2020 and March 2022, consecutive participants with stable coronary artery disease (CAD) were prospectively enrolled and underwent coronary CTA, cardiac MR, and invasive fractional flow reserve (FFR) within 2 weeks. Cardiac MR perfusion analysis was quantified by stress myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Hemodynamically significant stenosis was defined as FFR ≤ 0.8 or > 90% stenosis on invasive coronary angiography (ICA). The diagnostic performance of CT-FFR, MBF, and MPR was compared, using invasive FFR as a reference. The study protocol was completed in 110 participants (mean age, 62 years ± 8; 73 men), and hemodynamically significant stenosis was detected in 36 (33%). Among the quantitative perfusion indices, MPR had the largest area under receiver operating characteristic curve (AUC) (0.90) for identifying hemodynamically significant stenosis, which is in comparison with ML-based CT-FFR on the vessel level (AUC 0.89, p = 0.71), with comparable sensitivity (89% vs 79%, p = 0.20), specificity (87% vs 84%, p = 0.48), and accuracy (88% vs 83%, p = 0.24). However, MPR outperformed ML-based CT-FFR on the patient level (AUC 0.96 vs 0.86, p = 0.03), with improved specificity (95% vs 82%, p = 0.01) and accuracy (95% vs 81%, p < 0.01). ML-based CT-FFR and quantitative cardiac MR showed comparable diagnostic performance in detecting vessel-specific hemodynamically significant stenosis, whereas quantitative perfusion mapping had a favorable performance in per-patient analysis. ML-based CT-FFR and MPR derived from cardiac MR performed well in diagnosing vessel-specific hemodynamically significant stenosis, both of which showed no statistical discrepancy with each other.
Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 34
- Journal Issue
- 9
- Journal Page Range
- p. 5654-5665
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 55089184
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOLOGICAL STRESS; BLOOD FLOW; CHEST; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; CORONARIES; DATA COMPILATION; DIAGNOSIS; IMAGE PROCESSING; ISCHEMIA; MACHINE LEARNING; MAPPING; MYOCARDIUM; NMR IMAGING; PERFORMANCE; SENSITIVITY; SPECIFICITY
- Descriptors DEC
- ALGORITHMS; ANEMIAS; ARTERIES; ARTIFICIAL INTELLIGENCE; BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; DATA; DATA PROCESSING; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; HEART; HEMIC DISEASES; INFORMATION; LEARNING; MATHEMATICAL LOGIC; MUSCLES; ORGANS; PROCESSING; SYMPTOMS; TOMOGRAPHY; VASCULAR DISEASES