Comparison of time corrections using charge amounts, peak values, slew rates, and signal widths in leading-edge discriminators

  • 1. School of Electrical Engineering, Seoul National University, San 56-1, Shilim dong, Kwanak gu, Seoul 151-742 (Korea, Republic of)

Description

Leading-edge discriminators (LEDs) are one of the prominent discriminator technologies used in time-of-flight systems due to their simplicity, but they have large time walks such that the measured time should be corrected using amplitude information. In this article, we analyze off-line time corrections using four kinds of amplitude parameters, namely, peak values, slew rates, and signal widths, as well as charge amounts. For these corrections, we developed the front-end electronics (FEE) that can measure these amplitude parameters and performed time measurements with the developed FEE in an amplitude range of about 20 dB for various threshold conditions, which are the only adjustment in LEDs. Then, we off-line corrected the measured time using the amplitude parameters mentioned above and compared the corrected efficiencies by the used parameters and threshold conditions

Additional details

Identifiers

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
74
Journal Issue
6
Journal Page Range
p. 3115-3119
ISSN
0034-6748
CODEN
RSINAK

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
35057388
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
Descriptors DEI
AMPLITUDES; CORRECTIONS; DISCRIMINATORS; MODULATION; PEAKS; SIGNALS; TIME MEASUREMENT
Descriptors DEC
ELECTRONIC CIRCUITS

Optional Information

Notes
(c) 2003 American Institute of Physics.