Published March 2006 | Version v1
Journal article

Structural Safety Analysis Of Rear Door in ACP Hotcell Facility for Spent Fuel Treatment

  • 1. Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

Description

A demonstration facility for an advanced spent fuel conditioning process (ACP) is under construction at KAERI. In this hot cell facility, the rear door is frequently used since all process equipment and materials are taken in and out only through the rear door. Therefore, both the structural safety and stability of the door are essentially required for the safety of ACP facility. In this paper, the finite element analysis has been performed to investigate the structural safety under the impact condition between the rear door and the door frame. Also the possibility of the rear door being tumbled over by the impact force or the inertia force under a sudden stop condition has been evaluated. The analysis results demonstrate that the structural safety and stability of the rear door are sufficiently assured for both the impact and the accidental stop conditions.

Additional details

Publishing Information

Journal Title
Journal of the Korean Radioactive Waste Society
Journal Volume
4
Journal Issue
1
Series
3 refs, 9 figs, 3 tabs
Journal Page Range
p. 77-85
ISSN
1738-1894

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
42028295
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Descriptors DEI
FINITE ELEMENT METHOD; HOT CELLS; SAFETY; SAFETY ANALYSIS; SPENT FUELS
Descriptors DEC
CALCULATION METHODS; ENERGY SOURCES; EQUIPMENT; FUELS; LABORATORY EQUIPMENT; MATERIALS; MATHEMATICAL SOLUTIONS; NUCLEAR FUELS; NUMERICAL SOLUTION; REACTOR MATERIALS