Independent numerical simulations have been performed using the MCNP5 and SCALE5 radiation transport codes to evaluate the effectiveness of a concrete facility designed to shield personnel from neutron radiation emitted from DT neutron generators. The analysis considered radiation source terms of 14.1 MeV monoenergetic neutrons located at three discrete locations within the two test vaults in the facility, calculating neutron and photon dose rates at 44 locations around the facility using both codes. In addition, dose rate contours were established throughout the facility using the MCNP5 mesh tally feature. Neutron dose rates calculated outside of the facility are predicted to be below 0.01 mrem/h at all locations when all neutron generator source terms are operating within the facility. Similarly, the neutron dose rate in one empty test vault when the adjacent test vault is being utilized is also less then 0.01 mrem/h. For most calculation locations outside the facility the photon dose rates were less then the neutron dose rates by a factor of 10 or more

Availability note (English)

Available from http://dx.doi.org/10.1016/j.apradiso.2007.05.008

Additional details

Identifiers

DOI
10.1016/j.apradiso.2007.05.008;
PII
S0969-8043(07)00161-3;

Publishing Information

Journal Title
Applied Radiation and Isotopes
Journal Volume
65
Journal Issue
10
Journal Page Range
p. 1125-1133
ISSN
0969-8043
CODEN
ARISEF

Optional Information

Copyright
Copyright (c) 2007 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.