Comparison of CT and MRI artefacts from coils and vascular plugs used for portal vein embolization
- 1. Department of Diagnostic and Interventional Radiology, Charité, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany)
- 2. Department of General, Visceral and Transplantation Surgery, Charité, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany)
Description
Purpose: To retrospectively analyze the degree of artefacts in CT and MRI scans caused by coils and vascular plugs used for portal vein embolization (PVE). Materials and methods: All patients who underwent PVE between July 2011 and December 2012 and received either plug or coil embolization additional to particle embolization were retrospectively analyzed. Artefacts causes by embolization materials were measured in CT and MRI scans following PVE. Results: The sum of the artefact diameters caused from coils was significantly higher in CT (188.3 ± 26.1 mm) than in MRI T1 (50.5 ± 6.5 mm) or T2 imaging (39.5 ± 9.7 mm) (P < 0.05). In MRI, the diameter in T1 and T2 sequences did not differ significantly (P = 0.977). The sum of the artefact diameters from vascular plugs in MRI T1 sequences (62.5 ± 8.7 mm) was significantly higher than in CT (46.6 ± 4.8 mm; P < 0.05) and MRI T2 sequences (52.8 ± 3.8 mm; P < 0.05). Conclusion: PVE with particles and vascular plug causes significantly fewer artefacts than PVE with particles and coils on CT scans following embolization, which can be important in the event of vascular complications or in follow-up scans, should the patient become unresectable
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2014.01.004Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2014.01.004;
- PII
- S0720-048X(14)00022-9;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 83
- Journal Issue
- 4
- Journal Page Range
- p. 692-695
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 47005313
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; CAT SCANNING; COMPARATIVE EVALUATIONS; NMR IMAGING; PARTICLES; VASCULAR DISEASES; VEINS
- Descriptors DEC
- BLOOD VESSELS; BODY; CARDIOVASCULAR DISEASES; CARDIOVASCULAR SYSTEM; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.